Study on Dielectric Test Technology of ±800kV Flexible DC …

The dielectric test is one of the key type tests to assess the electrical performance of flexible DC converter valves. At present, flexible DC converter valves have reached UHV level. Therefore, it is of great significance to carry out research on insulation test technology of ±800kV flexible DC converter valves. To this end, this paper takes the ±800kV flexible …

A current-modulus derivative-based protection method in a flexible DC ...

This study develops a rapid protection method for flexible DC grids. Based on the principle of modulus decomposition, common-mode (CM) and differential-mode (DM) circuits of MMC, DC transmission line, and fault transition resistance under different faults are derived, and the synthesized equivalent circuit of DC grids are finally obtained. The method utilizes a …

Research on Fault Characteristics of DFIG Wind Farm with …

In [11], the influence of flexible DC converters of different structures on the fault voltage and current output of wind farms and flexible DC converters is summarized through simulation analysis. In [12], the AC-side fault characteristics of the flexible DC system of different types of wind turbines are studied through simulation models

Transient Stability of Grid-Forming Converters with Flexible DC …

This paper proposes a flexible dc-link voltage control scheme for grid-forming converters. In the approach, instead of cascading the dc-link voltage control with the power synchronization control, a paralleled connection of the two loops is employed, which leads to an additional control degree-of-freedom for flexible damping design. Further, the impact …

Design of a Flexible DC to AC Converter and its Control Using ...

Design of a Flexible DC to AC Converter and its Control Using Reinforcement Learning. Visualitza/Obre. design-of-a-flexible-dc-to-ac-converter-and-its-control-using-reinforcement-learning-jorgequinterobermejo.pdf (5,121Mb) Veure estadístiques d''ús d''UPCommons ...

AC-DC Bidirectional Fault Ride-through Control Strategy of Flexible DC ...

The flexible DC distribution network based on the modular multilevel converter (MMC) has developed rapidly in recent years. However, the negative sequence voltage and current generated after the AC side fault affect the stable operation of the system, and the surge of fault current after the DC side fault also seriously threatens the equipment safety. …

The Improved Topology and Control Strategy for the HCLC in the ...

The dc fault-current-limiting technique is extremely important for operation security and power supply reliability of the flexible dc grid. Generally, the dc reactor can effectively limit the dc fault current; however, it will result in negative influences on the system operation stability and dc circuit breaker (DCCB) isolating speed. The hybrid current-limiting circuit …

Fault-isolation Scheme for Flexible DC Distribution Networks with ...

Complete fault-isolation schemes for flexible DC distribution networks with multiple types of converters are rare. In this work, a fault-isolation scheme based on the new-type multi-port DC circuit breaker (MP-DCCB) and improved converters (modular multi-level converters; voltage source converters; and DC transformers) with current-limiting and fault-isolation …

Designof DC/DC Converter with GaN HEMT for Flexible DC …

The flexible DC system of the distribution grid is the rapid development direction of the flexible DC technology, and the DC/DC converter is the key equipment in the flexible DC system, which can realize the energy interaction between the electric vehicle and the distribution grid. In this paper, a GaN HEMT-based LLC resonant converter is designed, …

Flexibele DC energiemanager

Flexibele DC energiemanager. De DSM4.0 van Koch regelt en ontlast de DC link van frequentieregelaars en bedient vier deelgebieden: remenergie opslag; verhogen energie …

Equivalence and Transient Characteristics of Flexible DC …

Flexible DC transmission systems can renewable energy consumption and improve power supply reliability. However, the control response and topology of flexible DC converter leads to a different fault output from conventional synchronous generator. Based on topology and control strategy, the controller response of flexible DC converter after AC fault is …

Research on Influence of AC Neutral Grounding Impedance on …

Among all flexible DC system grounding methods, converter''s AC side grounding is an important one. Modular multilevel converter (MMC) with the third harmonic injection modulation strategy can improve the utilization of DC voltage. The third harmonic current will be generated when MMC with neutral point grounded on AC side adopts the third …

Energieopslagsystemen

De toonaangevende reeks lithium-ion-energieopslagsystemen van Atlas Copco vergroot het spectrum van geschikte toepassingen en biedt meer opties qua vermogen, waardoor …

Frequency Domain Impedance Based Protection for Flexible DC ...

The flexible DC distribution grid is suitable for distributed energy resource integration and DC load power supply. However, the fast-increasing fault current has a great impact on the system when a short circuit fault occurs. Besides, the existing main protections are easily affected by high resistance faults and converters. To solve the aforementioned problems, …

industriële batterijen

Components from the fields: battery accessories (e.g. electrolyte level measurement and electrolyte circulation, recombiners), energy converters (e.g. charging devices, energy …

Fault Component Differential Protection of DC Bus in Flexible DC ...

At present, the bus protection of the flexible DC distribution network refers to the AC protection scheme basically, and the existing bus protection methods can not remove the fault quickly and accurately. In order to achieve reliable and fast protection of bus fault in flexible DC distribution system, the fault characteristics of the DC bus in the flexible DC …

Solar365

Terwijl de wereld zich inzet voor een duurzamere toekomst, staat de noodzaak voor geïntegreerde, flexibele energieopslag centraal in de transitie naar groene energie. De …

Study on flexible DC grid based on H7-CSC | Semantic Scholar

The results show that the DC network model proposed by this paper can achieve the smooth start-up, stable operation, DC fault removal and system restart, which provides new ideas for the development of DC power grid in the future. In flexible DC transmission, if the DC fault occurs, not only the 2-level voltage source converter(VSC) and the modular multilevel …

Study on the overvoltage and insulation coordination of flexible DC ...

Flexible DC power distribution network is a new direction of flexible HVDC technology, it is now at the research stage. The advantages and technical difficulties of flexible DC distribution network are analyzed in this paper, and the flexible DC distribution demonstration project prepared to build in Shenzhen is briefly introduced. The …

Inter-Pole Short Circuit Protection Strategy for Flexible DC ...

Inter-electrode short-circuit fault in flexible DC distribution network is a very serious fault, because the current amplitude is extremely high and the spread speed is fast. Therefore, reliable identification and accurate positioning are urgent problems to be solved. This paper proposes a strategy combining the delay blocking of the converter valve and the fast line …

Flexible DC distribution line protection principle based on distance ...

AbstractAiming at the issue of unsatisfactory selectivity of single‐terminal protection, and poor speed and high requirements for data synchronization of double‐terminal protection in flexible DC distribution networks, an artificial intelligence (AI)‐based method is proposed to obtain the best clustering centres through unsupervised clustering analysis of historical …

Fault Characteristic Analysis and a Novel Pilot ...

Due to the pseudo-bipolar structure of the flexible DC distribution network, the short-circuit current caused by a pole-to-ground fault is weak. The fault characteristics, particularly the steady-state fault characteristics, are not prominent. Therefore, pole-to-ground fault diagnosis and protection have become more challenging. This paper theoretically studies …

A Pilot Protection Scheme of flexible DC Transmission Line

To solve the problems of flexible DC line protection, A backup protection principle for flexible DC transmission lines based on the direction of low-frequency reactive power is proposed in this paper. First of all, DC reactive power is used to characterize the frequency characteristics of line distribution parameters. Subsequently, the direction of the faulty DC …

Alles over de grote energieopslag systemen van SemperPower

Flexibele energieopslag is wat wind- & zonnepark ontwikkelaars, netwerkbedrijven (DSO''s & TSO''s) en industriële afnemers nodig hebben. SemperPower biedt de oplossing door …

Hybrid Generalized Short Circuit Ratio Considering the Flexible DC ...

The static voltage stability of hybrid multi-infeed high voltage direct current (HMIDC) system composed of voltage source converter based HVDC (VSC-HVDC) and line commutated converter based HVDC (LCC-HVDC) is ought to be considered. In addition, generalized short circuit ratio (gSCR) is the index of static voltage stability only based on the …

Non-permanent Pole-to-pole Fault Restoration Strategy for Flexible DC ...

As the structures of multiple branch lines (MBLs) will be widely applied in the future flexible DC distribution network, there is a urgent need for improving system reliability by tackling the frequent non-permanent pole-to-pole (P-P) fault on distribution lines. A novel fault restoration strategy based on local information is proposed to solve this issue. The strategy firstly …

An improved second order generalized integrators phase locked …

Accurate and fast phase locking is the primary condition for flexible DC transmission to realize reliable control. When the power grid is unbalanced or contains high-order harmonics, the traditional second order generalized integrator (SOGI) itself has the defect of strong dependence on the input signal frequency. Therefore, this paper proposes ...

Comparison and analysis of the fault arc characteristics of flexible DC ...

The primary and secondary arc characteristics of the transient single-pole ground fault on the transmission lines are simulated and compared with the arc in AC system. It is shown that the arc extinction time of the flexible DC transmission system is lesser than that of the AC system at the same voltage level.

Innovatieve oplossingen voor energieopslag: schaalbaarheid en …

Modulaire energieopslagsystemen bestaan uit kleinere onderling verbonden eenheden, waardoor flexibele schaalbaarheid, vereenvoudigde installatie en verbeterde veerkracht …

The Potential Impact of Flexible DC Transmission and …

Flexible DC transmission is becoming a promising technology for HV and MV links, where large amount of power must be transported, long distances are involved and integration of renewables is sought. The introduction of advanced power electronic converters, with fast and low loss switches, is dramatically improving reliability of DC lines and shortening the …

Research on Melting Scheme for Overhead Line of Flexible DC …

Ice coating caused by ice and snow disasters is extremely harmful to DC power grids. Therefore, the research and application of ice melting technology is of great significance for DC grids to combat ice disasters. According to the advantages and limitations of a variety of DC transmission line melting methods, the paper decided to select the two types of …

Fabrikant van batterij-energieopslagsystemen | DFD-energie

Bent u op zoek naar een fabrikant van energieopslagsystemen voor batterijen? DFD Energy is gespecialiseerd in het produceren van batterij-energieopslagsystemen met jarenlange …

Vragen en antwoorden

algemeentwijfel

Welke producten produceert u?

Wij produceren de meeste producten die verband houden met zonne-energie, zoals zonnepanelen, netkasten, energieopslagbatterijen, omvormers voor fotovoltaïsche energieopslag, kleine busbars, draagbare energiecentrales...

Wat is de prijs van uw producten?

Omdat de behoeften van elke klant anders zijn, is de prijs ook anders. Als u geïnteresseerd bent in onze producten, neem dan contact met ons op via e-mail en wij geven u een referentieprijs Gebaseerd opuw behoeften.

Hoe kan ik contact met u opnemen?

U kunt contact met ons opnemen via de optie 'Contact' op de pagina. Wij nemen dan binnen 24 uur contact met u op.

Hoe kan ik een aanvraag voor aftersales service indienen?

Wij hebben toegewijd personeel om contact met u op te nemen. Als u problemen ondervindt tijdens het gebruik, kunt u ons bellen en wij zullen ze zo snel mogelijk voor u oplossen.

Wat moet ik doen als ik de parameters van deze producten niet goed begrijp?

Onze verkoopmedewerkers adviseren u over de producten die het beste bij uw behoeften passen en zorgen ervoor dat aan al uw behoeften wordt voldaan tegen de laagste prijs.

Van maandag tot zaterdag: 8.00 - 21.00 uur
Zondag: 10.00 - 20.00 uur
Sjanghai, China
FEng-lijn district

naar boven